After Running the Provision Tool
Once the servers are provisioned, run the post provision script to:
Configure iDRAC IP or BMC IP if
bmc_nic_subnet
is provided ininput/provision_config.yml
.Configure Infiniband static IPs on remote nodes if
ib_nic_subnet
is provided ininput/provision_config.yml
.Set hostname for the remote nodes.
Invoke
network.yml
andaccelerator.yml
to install OFED, CUDA toolkit and ROCm drivers.Create
node_inventory
in/opt/omnia
listing provisioned nodes.cat /opt/omnia/node_inventory 172.29.0.100 service_tag=XXXXXXX operating_system=RedHat 172.29.0.101 service_tag=XXXXXXX operating_system=RedHat 172.29.0.102 service_tag=XXXXXXX operating_system=Rocky 172.29.0.103 service_tag=XXXXXXX operating_system=Rocky
Note
Before post provision script, verify redhat subscription is enabled using the rhsm_subscription.yml
playbook in utils only if OFED or GPU accelerators are to be installed.
To run the script, use the below command::
ansible-playbook post_provision.yml